SBL-SCB-00016: Inherited socket (0) is invalid. The SCBroker listening port may already be in use by another process


STEPS
-----------------------

The issue can be reproduced at will with the following steps:
1. Login to siebel server box.
2. Run siebenv.sh
3. Run start_server all
4. Server is not coming up and throwing error.

BUSINESS IMPACT
-----------------------

The issue has the following business impact:
Customer has schedule a downtime to restart the siebel servers.As the siebel server is not come up all the Siebel Marketing users will affect,it will impact their production.


CAUSE
-----------------------

Issue is caused due to SCBroker component port is used by some other process in the System.


SOLUTION
------------------------

1)Open a command prompt in siebel server.
2)Run netstat -a
3)verify and kill if any process using  port 2321 or reboot the OS to release the 2321 port.
4)Bring up the Siebel server and verify the status.